RETIRED ›
This product is no longer available and has been replaced by: HMP60-ET. Some accessories, replacement parts, or services may still be available.
HMP60-ETR Temperature/RH Probe for ET Station with Shield Adapter
Services Available
Repair No
Calibration No
Free Support No

Overview

The HMP60-ETR is the replacement temperature and RH sensor for older ET stations. The sensor's cable terminates in a connector and is the ideal length for attachment to the ET107 or ET106 ETo Weather Station. The HMP60-ETR includes an adapter that allows the sensor to fit in a R. M. Young radiation shield.

The HMP60-ETR measures both temperature and relative humidity and is suitable for long-term, unattended monitoring. The humidity component features a field-replaceable chip, which eliminates downtime typically required for the recalibration process.

Read More

Images

Detailed Description

The HMP60 uses the INTERCAP® capacitive RH chip. This chip is field-replaceable, which eliminates the downtime typically required for the recalibration process.

The radiation shield is a 41303-5A shield modified to mount to an ET station. This six-plate naturally-aspirated radiation shield has a louvered construction that allows air to pass freely through the shield thereby keeping the probe at or near ambient temperature.

Specifications

Supply Voltage 5 to 28 Vdc (typically powered by datalogger’s 12 V supply)
Typical Current Consumption 1 mA
Maximum Current Consumption 5 mA
Filter Description 0.2 µm Teflon membrane
Settling Time 1 s
Sensor Body Material AISI 316 stainless steel
Filter Cap Material Chrome-coated ABS plastic
Classification IP65
Filter Diameter 1.2 cm (0.5 in.)
Sensor Diameter 1.2 cm (0.5 in.)
Sensor Length 7.1 cm (2.8 in.)
Cable Length 137.16 cm (54 in.)

Temperature

Temperature Sensor 1000 ohm Platinum Resistance Thermometer
Measurement Range -40° to +60°C
Accuracy ±0.6°C

Relative Humidity

Sensor Vaisala’s INTERCAP capacitive chip
Measurement Range 0 to 100% RH (non-condensing)
Accuracy (0 to 90% RH)
  • ±5% (-40° to 0°C)
  • ±3% (0° to 40°C)
  • ±5% (40° to 60°C)
Accuracy (90 to 100% RH)
  • ±7% (-40° to 0°C)
  • ±5% (0° to 40°C)
  • ±7% (40° to 60°C)

Compatibility

This sensor is compatible with older ET107, T107, and WSPRO2 stations and retired ET stations such as the ET106, T106, and WSPRO.

Note: The HMP60-ETR includes an adapter that allows the sensor to fit in an R. M. Young radiation shield. The R. M. Young radiation shield does NOT have wingnuts. If you see wingnuts, the appropriate replacement sensor for your station is the HMP60-ETS.

Listed Under