NL120 Ethernet Interface
Services Available
Repair Yes
Calibration No
Free Support Yes

Overview

La NL120 le permite al Datalogger comunicarse sobre una red local o a una conexión de Internet dedicada. Se utiliza el protocolo TCP/IP. Este dispositivo esta diseñado para conectarse al puerto de periféricos de 40 pines disponible en el CR1000 o en el CR3000.

Read More

Benefits and Features

  • Compatible with CR1000 and CR3000
  • Connects a data logger to a network
  • Smallest Ethernet module available for the CR1000 and CR3000

Images

Detailed Description

The NL120 uses a straight through cable when the cable is run from a hub to the NL120. A 10baseT Ethernet crossover cable is used if the cable is run directly from the computer to the NL120. For cable lengths longer than 9 feet, either a shielded 10baseT Ethernet cable or the 28033 surge protector needs to be used.

The NL120 is set up using the Device Configuration utility (DevConfig). DevConfig is bundled with our PC400, RTDAQ, and LoggerNet software and is available, at no charge, from: www.campbellsci.com/downloads

Specifications

Power Requirements 12 V (supplied through the data logger’s peripheral port)
Ethernet Speed 10Base-T (10 Mbps), half-duplex
Typical Current Drain 20 mA
Dimensions 10.2 x 6.4 x 2.8 cm (4.0 x 2.5 x 1.1 in.)
Weight 66.62 g (2.35 oz)

EMI and ESD Protection

European Standards Meets requirements for a class A device under European Standards.
Application of Council Directive(s) 89/336/EEC as amended by 89/336/EEC and 93/68/EEC
Standards to Which Conformity Is Declared EN55022-1; 1995 and EN50082-1: 1992

Software Requirements

LoggerNet Version 3.2 or later
PC400 Version 1.3 or later
DevConfig Version 1.5 or later

Compatibility

Please note: The following shows notable compatibility information. It is not a comprehensive list of all compatible products.

Dataloggers

Product Compatible Note
CR1000 (retired)
CR200X (retired)
CR206X (retired)
CR211X (retired)
CR216X (retired)
CR295X (retired)
CR3000 (retired)
CR3000 (retired)
CR5000 (retired)
CR800 (retired)
CR850 (retired)
CR9000X (retired)

Mounting Equipment

Product Compatible Note
ENC10/12
ENC10/12R Attached to a CR1000 or CR3000
ENC12/14 Attached to a CR1000
ENC14/16 Attached to a CR1000 or CR3000
ENC16/18 Attached to a CR1000 or CR3000

Additional Compatibility Information

Ethernet Cable

A 10baseT Ethernet straight through cable is used when the cable is run from a hub to the NL120. A 10baseT Ethernet crossover cable is used if the cable is run directly from the computer to the NL120. For cable length longer than 9 ft, the 10baseT Ethernet cable must be shielded or the 28033 surge suppressor must be used.

Data Logger Considerations

The NL120 fastens onto the data logger's 40-pin peripheral port. This means that the NL120 is only compatible with the CR1000 and CR3000. It is NOT compatible with the CR800, CR850, CR200X, CR5000, or CR9000X dataloggers.

Documents

Product Brochures


Frequently Asked Questions

Number of FAQs related to NL120: 1

  1. Yes. For example, the NL115 allows the CR1000 to communicate over a local network or a dedicated Internet connection via TCP/IP. 

Casos de estudio

North Carolina: Monitoring “Green” Hotel
When Dennis Quaintance decided to build the Proximity Hotel in Greensboro, North Carolina, he knew......read more
Utah: Water-Supply SCADA System
In 2010, Trenton and Amalga, two northern Utah towns separated by only a few miles,......read more